Regulated by Texas Department of Licensing and Regulation (TDLR). 4 cert types in the database.
Any building operating a boiler covered by Texas Health & Safety Code ch.755 (most commercial + multifamily boilers)
Texas Health and Safety Code ch.755
Penalty for missing: TDLR assesses administrative penalties per boiler per violation; operators have been fined tens of thousands of dollars for skipped annual inspections. Late Inspection Fees effective June 15, 2026 (16 TAC 65.61): $25/day 0-30 days overdue, $50/day 31-60 days, $100/day 61+ days, accruing until the inspection is completed.
Any building with an elevator, escalator, or other conveying device regulated by TDLR
Texas Occupations Code ch.754; 16 Tex. Admin. Code ch.74
Penalty for missing: Administrative penalties and sanctions per violation (TDLR); late inspection-report filing costs $10 per 30-day period after the 60-day submission window.
Buildings with fire alarm, sprinkler, or suppression systems (local fire code enforcement + state licensing of firms)
Texas Insurance Code ch.6002 (fire protection licensing)
Texas buildings with backflow prevention assemblies protecting against health hazards
30 Texas Admin Code 290.44(h)(4)
Certmill's database lists 4 requirement types for Texas, including boiler inspection, elevator inspection, fire protection itm, backflow testing. Every rule cites the official agency page, and cities inherit their state's requirements automatically.
Any building operating a boiler covered by Texas Health & Safety Code ch.755 (most commercial + multifamily boilers) The required cycle is annual to biennial by class under Texas Health and Safety Code ch.755, administered by TDLR Boiler Safety.
Any building with an elevator, escalator, or other conveying device regulated by TDLR The required cycle is annual under Texas Occupations Code ch.754; 16 Tex. Admin. Code ch.74, administered by TDLR Elevator Safety.
Buildings with fire alarm, sprinkler, or suppression systems (local fire code enforcement + state licensing of firms) The required cycle is annual (NFPA 72/25 ITM) under Texas Insurance Code ch.6002 (fire protection licensing), administered by Texas Insurance Code ch.6002 firms; local fire marshal enforcement.
Texas buildings with backflow prevention assemblies protecting against health hazards The required cycle is annual under 30 Texas Admin Code 290.44(h)(4), administered by TCEQ + local water purveyor.
Check the requirement cards on this page: any facade or exterior wall rule shows its trigger (usually a story or height threshold), cycle, and the official ordinance source. Certmill adds facade requirements automatically for buildings of 7 or more floors.
Add the building in Certmill, pick Texas, and check the equipment you run. The requirements expand into a deadline calendar with countdowns, 60-day alerts, and an evidence binder PDF.